Assembly instructions with explanatory notes on the mounting of electronic safety converters for low voltage halogen incandescent lamps.
Mandatory Regulations
|
DIN VDE 0100 |
Erection of low voltage installations |
|
EN 60598–1 |
Luminaires – part 1: general requirements and tests |
|
EN 61000–3–2 |
Electromagnetic Compatibility (EMC) – part 3: maximum values – main section part 2: maximum values for mains harmonics (device input current up to and including 16 A per conductor) |
|
EN 55015 |
Maximum values and methods of measurement for RFI suppression in electrical lighting installations and similar electrical appliances |
|
EN 61547 |
Installations for general lighting purposes – EMC immunity requirements |
|
EN 61347–1 |
Operating devices for lamps – part 1: general and safety requirements |
|
EN 61347–2–2 |
Operating devices for lamps – part 2–2: Special requirements for DC- or AC-powered electronic converters for incandescent lamps |
|
EN 61047 |
DC- or AC-powered electronic converters for incandescent lamps – performance requirements |
Designations for VS Converters
Designations for electronic converters are first listed by the name of the product family, which in each case reflects the visible product properties. The type designation should be read as follows:
|
EST |
60 |
/12 |
.388 |
|
Electronic Safety Transformer |
Max. Wattage |
Lamp Voltage |
Serial Number |
Mechanical Mounting
|
Mounting position |
Any |
|
|
|
|
Clearance |
Min. of 0.1 m from walls, ceilings, insulation; min. of 0.1 m from other electronic converters; min. of 0.25 m from sources of heat (lamp) |
|
|
|
|
Surface |
Solid; device must not be allowed to sink into insulation materials |
|
|
|
|
Mounting location |
In dry rooms or in luminaires, cases, casings or similar in the instance of built-in converters |
|
|
|
|
Fastening |
Independent converters: using screws, Ø 4 mm
Built-in converters: fix M8 nut on the threaded stud |
|
|
|
|
Heat transfer |
If the electronic converter is destined for installation in a luminaire, sufficient heat transfer must be ensured between the converter and the luminaire casing. During operation, the tc point must not exceed the specified value. |
|
|
Click on the image to get a PDF-file with the assembly instructions of electronic converters.
|