VOSSLOH-SCHWABE
   
   
   
 
General
Transformers and converters for low-voltage halogen lamps
Electronic converters
Electromagnetic transformers
Assembly instructions of electromagnetic transformers
Dimmability of VS transformers and VS converters
Conductors for low-voltage installations
Lampholders for low-voltage halogen lamps
Bases for low-voltage halogen lamps
Lampholders for mains voltage halogen lamps
Bases for mains voltage incandescent lamps
Fluorescent Lamps
Discharge Lamps
     

Assembly instructions of electronic converters

     

Assembly instructions with explanatory notes on the mounting of electronic safety converters for low voltage halogen incandescent lamps.

Mandatory Regulations

DIN VDE 0100

Erection of low voltage installations

EN 60598–1

Luminaires – part 1: general requirements and tests

EN 61000–3–2

Electromagnetic Compatibility (EMC) – part 3: maximum values – main section part 2: maximum values for mains harmonics (device input current up to and including 16 A per conductor)

EN 55015

Maximum values and methods of measurement for RFI suppression in electrical lighting installations and similar electrical appliances

EN 61547

Installations for general lighting purposes – EMC immunity requirements

EN 61347–1

Operating devices for lamps – part 1: general and safety requirements

EN 61347–2–2

Operating devices for lamps – part 2–2: Special requirements for DC- or AC-powered electronic converters for incandescent lamps

EN 61047

DC- or AC-powered electronic converters for incandescent lamps – performance requirements


Designations for VS Converters

Designations for electronic converters are first listed by the name of the product family, which in each case reflects the visible product properties. The type designation should be read as follows:

EST

60

/12

.388

Electronic Safety Transformer

Max. Wattage

Lamp Voltage

Serial Number



Mechanical Mounting

Mounting position

Any

 

 

Clearance

Min. of 0.1 m from walls, ceilings, insulation; min. of 0.1 m from other electronic converters; min. of 0.25 m from sources of heat (lamp)

 

 

Surface

Solid; device must not be allowed to sink into insulation materials

 

 

Mounting location

In dry rooms or in luminaires, cases, casings or similar in the instance of built-in converters

 

 

Fastening

Independent converters: using screws, Ø 4 mm

Built-in converters: fix M8 nut on the threaded stud

 

 

Heat transfer

If the electronic converter is destined for installation in a luminaire, sufficient heat transfer must be ensured between the converter and the luminaire casing. During operation, the tc point must not exceed the specified value.

  PDF-File with further information Click on the image to get a PDF-file with the assembly instructions of electronic converters.